Adhunik

Adhunik switchgears   Pvt. Ltd, DEL

Our Products

Switchgears

Prewired

At Adhunik basics of the all the devices are very strong and unique.

MCB

At Adhunik basics of the all the devices are very strong and unique.

MCCB

At Adhunik basics of the all the devices are very strong and unique.

RCCB

At Adhunik basics of the all the devices are very strong and unique.

MCB

At Adhunik basics of the all the devices are very strong and unique. Body is made of “Polybutaline terapythalate Polyesterpolymer chip ”which has highly desirable thermal & electrical properties such as fire get extinguished when it moves from one molecule to another in such kind of material. “Action is look like of Fire proof materials” Making Breaking Fixed and Moving Contact- Moving- Brass plate inlayed by Pure Silver Making room for electrons to flow in a large area with minimum resilience. Fixed contact specially designed to make sure that there is no air gap between the two contacts even after large no of operations, Make brake is perfect ,No secondary Arc can develop - “Action is a weld Free mechanism” A common problem with many other designs Arc chute Tri coating (once with Zinc twice with Nickel Gold) on Arc splinters creates a suction effect quenching arc much faster than other MCBs -“Action is a Safe MCB”.

MCB capacity includes 2AMP to 63AMP and also includes B & C series, SP, SPN, DP, TP & TPN.

MCB
mccb-manufacturer

MCCB

Different Frame sizes as per suitability of installation, Thermal magnetic Electronic and Microprocessor trip units-as per suitability of application, power supply can be connected from top (or bottom reverse feeding in selected models).Short Circuit current is limited to very low values due to reflex tripping feature. In case of fault occurrence only the circuit breaker immediately upstream from the fault will trip, due to limited breaking capacity of Adhunik MCCBs this discrimination feature allows cascading among no. of MCCBs installed thereby upstream circuit breaker protects all circuit breakers placed downstream as well as other feeders will remain active in case of fault occurrence in one of output feeders. Models available with source changeover system (main source and alternate source), communication option, optimized auxiliaries.

Conforming to IS:13947-1&2& IEC 60947-1&2 with 10kA to 65kA breaking capacity also complying with IEC 68-2-6 Vibration test and IEC 68-2-27 shock test, IEC 60529-IP Degree of protection ,IEC 62262-IK degree of protection against mechanical impact.

 

RCCB

Provides ground fault protection by monitoring the leakage of the current to ground. RCCB will trip when ground faults are detected in excess of the Gf trip rating of it. The product can also detect and trip when there is a current differential between the live line and neutral line ,and therefore protect people from electric shock. These devices provide GF protection and life protection and are used in series with standard MCBs which provide overload and short circuit protection.The product can be used as a main device providing GF and life protection for several MCB branch devices.

16A-100A , 2pole 240V/4pole 240/415VAC 50hz,DIN rail mounting, Conforming to IS:12640-1:2000& IEC 6 1008-1

 

RCCB-MANUFACTURER